Гаматана Daikin за запазване на топлината при вентилация подобрява енергийната ефективност и осигурява
Air Treatment Equipment CEK HARGA=> KATALOGUE=> SPESIFIKASI=> Heat Reclaim Ventilator — VAM series Model Names VAM150GJVE, VAM250GJVE, VAM350GJVE, VAM500GJVE, VAM650GJVE, VAM800GJVE, VAM1000GJVE, VAM1500GJVE, VAM2000GJVE Improved Enthalpy Efficiency*1 Higher External Static Pressure*2 Enhanced Energy Saving Functions Seri VAM ini memberikan efisiensi entalpi yang lebih tinggi*1, karena kinerja elemen film tipis yang sangat ditingkatkan. Selain itu, tekanan statis eksternal yang ditingkatkan*2 menawarkan lebih banyak fleksibilitas untuk pemasangan. Seiring dengan ketiga peningkatan luar biasa ini, operasi pendinginan malam hari gratis berkontribusi pada konservasi energi dan lingkungan yang lebih nyaman.
TotalHeat Exchanger HRV (Heat Reclaim Ventilation) 4PA - 2017.08 Operation manual 2 Names of parts Refer to figure 1 (models VAM350~1000F) and figure 2 (models VAM1500~2000F) Operation Explanation for systems This product is operated differently depending on the system configuration.Residential Light Commercial Commercial Home > Commercial > Ventilation Units > Energy Recovery Ventilator VAM_GVJU Overview Features Resources This product is designed to maintain good indoor air quality by providing sufficient levels of fresh outside air and recover waste heat from extracted air leaving the conditioned zone. This new ERV unit is fully compatible with Daikin’s DIII-NET communications. Provides energy-saving heat recovery ventilation via a new heat exchanger with high temperature and enthalpy recovery efficiency Design flexibility thanks to high static pressure fans and the capability for use in a wide range of climates 5°F to 122°F DB and 80% RH or less* Wide range of functions such as independent operation, interlock with other HVAC systems and automatic night purge to reduce cooling loads and increase energy savings Interlocked simultaneous operation with VRV indoor units through a single controller Auto mode switches the ventilation mode total heat exchange mode to bypass mode according to the operating status of air conditioner system Pre-cooling/heating control function to delay the start of ventilation during air conditioner start-up for higher energy savings Supply and exhaust fresh-up operation modes to control pressure within a space Filter sign and display reset notifies when filter changes are required ESP as high as Sound levels as low as dBA for sound sensitive installation locations * Note Certified in accordance with the AHRI ERV Certification Program, which is based on AHRI Standard 1060. Certified units may be found in the AHRI Directory at Performance characteristics certified to AHRI Standard 1060 based on the following conditions - The cooling effectiveness shall be based on 95°F DB / 78°F WB for the entering supply air and 75°F DB / 63°F WB for the entering exhaust air, at a leaving supply airflow of both 100% and 75% of the rated airflow. - The heating effectiveness shall be based on 35°F DB / 33°F WB for the entering supply air and 70°F DB / 58°F WB for the entering exhaust air, at a leaving supply airflow of both 100% and 75% of the rated airflow. UnityAir-con Systems - Offering Daikin Heat Reclaim Ventilation System, Ventilation Systems, Air Ventilation, एयर वेंटिलेशन सिस्टम, वायु-संचालन प्रणाली in Delhi, Delhi. Get best price and read about company. Get contact details and address| ID: 11360450997 Product Highlights View AR View 360 Fresh air supply and better indoor air quality for confined space. Air flow rate 150 – 2,000 m³/hour Daikin’s HRV Heat Reclaim Ventilation recovers heat energy lost through ventilation and holds down room temperature changes caused by ventilation, thereby maintaining a comfortable and clean environment. This also curbs the load on the air conditioning system and conserves energy. In addition, the HRV is interlocked to Daikin’s VRV system, SkyAir and other air conditioning systems and automatically switches over ventilation mode, further increasing the effects of energy conservation. HRV operation has been centralized on the air conditioner remote controller allowing total control over air conditioning and ventilation with a simple configuration. VAM – How It Works The fresh air is supplied to the office by air discharge grills connected to the VAM Supply Air duct. Heat Recovery Ventilation with Simultaneous Supply and Exhaust A compact unit packed with Daikin’s cutting-edge technologies The heat exchange element uses a upgraded High Efficiency Paper HEP that has superior moisture-absorption and humidifying properties and doubles the current efficiency of moisture absorption. The heat exchange unit speedily recovers heat contained as latent heat vapor. The element is made of a material with superior flame-resistant properties and is treated with an anti-molding agent. Advanced Energy-Saving Ventilation by Interlocking with VRV Indoor Unit • Pre-cool, Pre-heat control • Auto-ventilation mode changeover switching • Night-time free cooling operation Air Conditioning Load Reduced by Approximately 31%* Filtration Unit Option Removes particulate matter present in the outdoor air, as well as sulfur oxides and nitrogen oxides, providing clean fresh air to the indoor ambient. • filter Removes 99% or more of μm particulate matter. • Activated Carbon filter Removes sulfur oxides and nitrogen oxides Double-layered efficient filtration filters are double-layered. filters are double-layered. 1. The front filter effectively remove large particles. 2. The filter layer contains a large amount of static electricity to capture particulate matter effectively. Electrostatic Dust Collection Filter More Efficient and Longer Lasting Effect The filter layer contains a large amount of static electricity to capture particulate matter effectively, including those smaller than the grid mesh. The filter is difficult to be blocked by particles and has good ventilation and long life span. CO2 Sensor Optional Kit Connection for VAM / VKM Series The CO2 sensor controls airflow so that it best matches the changes of CO2 level in the room. This prevents energy losses from over-ventilation while maintaining indoor air quality with optional CO2 sensor. You are now leaving Daikin Malaysia Once you link to another web site, you are subject to the terms and conditions of that web site, including but not limited to its privacy policy. CANCEL CONTINUE
CleanAir stock a large range of air ventilation and diffusion hardware, used to and create individual systems bespoke to client requirements. As a starting point the forms of ventilation to consider are: Ventilation and Heat Reclaim units for air conditioned climate control. Evaporative Air Conditioning for fresh air ventilation and cooling.
Product categoryVRV Air Conditioner›Heat Reclaim VentilationModel HRV VAM250GJVE, VAM500GJVE, VAM650GJVE, VAM800GJVE, VAM1000GJVE, VAM1500GJVE, VAM2000GJVESpecificationMODELVAM250GJVEVAM500GJVEVAM650GJVEVAM800GJVEVAM1000GJVEVAM1500GJVEVAM2000GJVEPower Supply1-phase, 220-240 V/ 220 V, 50 HzTemp. ExchangeEf ciency50/60 HzUltra-High%75/7574/7475/7572/7278/7872/7277/77High75/7574/7475/7572/7278/7872/7277/77Low79/7980/ ciency50/60 HzFor HeatingUltra-High%71/7267/ CoolingUltra-High%63/6355/5561/6161/6164/6461/6162/62High63/6355/5561/6161/6164/6461/6162/62Low66/6659/ HzHeatExchangeModeUltra-HighW137/141248/270342/398599/680635/7601,145/1,3001,289/1,542High120/125225/217300/332517/597567/648991/1,1441,151/1,315Low60/59128/136196/207435/483476/512835/927966/1,039Bypass ModeUltra-HighW137/141248/270342/398599/680635/7601,145/1,3001,289/1,542High120/125225/217300/332517/597567/648991/1,1441,151/1,315Low60/59128/136196/207435/483476/512835/927966/1,039Sound Level 50/60 HzHeat ExchangeModeUltra-HighdBA27-29/ ModeUltra-HighdBA steel plateInsulation MaterialSelf-extinguishable polyurethane foamDimensions HXWXDmm278X810X551306X879X800338X973X832387X1,111X832387X1,111X1,214785X1,619X832785X1,619X1,214Machine Weighkg2432455567129157Heat Exchange SystemAir to air cross ow total heat Sensible heat+latent heat exchangeHeat Exchange Element MaterialSpecially processed non-ammable paperAir FilterMultidirectional brous eecesFanTypeSirocco fanAir ow Rate50/60 HzUltra-Highm3/h250/250500/500650/650800/8001,000/1,0001,500/1,5002,000/2,000High250/250500/500650/650800/8001,000/1,0001,500/1,5002,000/2,000Low155/155320/295500/470700/670860/8401,320/1,2601,720/1,580External Static Pressure50/60 HzUltra-HighPa70/96105/15085/125133/170168/192112/150116/ Duct Diametermmø150ø 200ø 250ø 350Unit ambient condition-15°C–50°CDB, 80%RH or lessAS A PART OF CONTINOUS DEVELOPMENT AND UPGRADATION THE PRODUCT IMAGE/ACCESSORY/FEATURE/SPECIFICATION MAY BE DIFFERENT FROM ACTUAL PRODUCT AT THE TIME OF PURCHASE.
CarrierChillers Used with Heat Recovery. Buildings are responsible for 40 percent of total energy consumption. Of the energy consumed in commercial buildings, 43 percent is used for space and water heating. If a more efficient means of providing heat could be implemented it would represent a tremendous opportunity to reduce energy consumptionWhyDaikin. Daikin guarantees your comfort in every facet of our service, right through from research and development to installation and enjoyment. Malfunction of transmission (between heat reclaim ventilation unit and fan unit) Possible Cause: • Defect of fan unit PCB. • Defect of connecting wire between (1) and (2) Malfunction Code: 95 03** Daikin Europe N.V. est autorisé à compiler le Dossier de Construction Technique. 04 ** Daikin Europe N.V. is bevoegd om het Technisch Constructiedossier samen te stellen. 05 ** Daikin Europe N.V. está autorizado a compilar el Archivo de Construcción Técnica. 06 ** Daikin Europe N.V. è autorizzata a redigere il File Tecnico di