TotalHeat Exchanger Heat Reclaim Ventilator -with DX Coil-MODELS (Ceiling mounted duct type) With DX coil & HumidifierWith DX coil VKM50GBMV1 VKM50GBV1 VKM80GBMV1 VKM80GBV1 VKM100GBMV1 VKM100GBV1 Heat Reclaim Ventilator Heat Reclaim Ventilator

VAM-HVE VAM-HVE Heat Reclaim Ventilator Daikin also offers heat reclaim ventilator systems; our VAM-HVE series are compact, energy efficient and can operate under a wide outdoor operating temperature range -15 to 50°C. These units provide high enthalpy efficiency due to the greatly enhanced performance of the thin film element. Furthermore, ESP* of up to 235Pa offers greater design flexibility to your air conditioning solution. Other features include Night Purge Operation night time free-cooling, interlocked operation with VRV Cassette presence sensor and optional CO2, indoor & outdoor humidity sensors for optimal operation. By incorporating heat reclaim ventilators into your air conditioning design, heat loads can be reduced and your plan size can be better optimised. *Max ESP varies from 130 Pa to 235 Pa depending on the model class Download Brochure All Daikin air conditioners exceed MEPS requirements, in line with Daikin’s commitment to providing energy efficient, quiet, simple to use and reliable air conditioning solutions. Technical Specifications Available Options System Reverse Cycle Capacities Indoor Type Heat Reclaim Ventilator Power Supply Refrigerant VAM-HVE Flyer Our VAM-HVE series are compact, energy efficient and can operate under a wide outdoor operating temperature range. Furthermore, improved external static pressures offer greater design flexibility to support variety of duct layouts. Send the brochure to me. Enter your email below to receive the brochure link in your inbox
Animation Your nose works as a kind of heat-recovery ventilation system. When you breathe out (1), your nasal passages are warmed by heat from the outgoing air (2). When you breathe in, the cold incoming air picks up some of this heat (3), which would otherwise have been wasted. As a child, you might have learned that it's better to breathe Available in Capacities Refrigerant Daikin also offers heat reclaim ventilator systems; our VAM-HVE series are compact, energy efficient and can operate under a wide outdoor operating temperature range -15 to 50°C. These units provide high enthalpy efficiency due to the greatly enhanced performance of the thin film element. Furthermore, ESP of up to 235Pa offers greater design flexibility to your air conditioning solution. Other features include Night Purge Operation night time free-cooling, interlocked operation with VRV Cassette presence sensor and optional CO2, indoor & outdoor humidity sensors for optimal operation. By incorporating heat reclaim ventilators into your air conditioning design, heat loads can be reduced and your plan size can be better optimised. Download Brochure Engineering Data All Daikin air conditioners exceed MEPS requirements, in line with Daikin’s commitment to providing energy efficient, quiet, simple to use and reliable air conditioning solutions. Contact a Daikin Sales Engineer A Daikin Sales Engineer will assess, plan and install the right air conditioning solution for you, with creativity and sensitivity to the needs of your family or business. AAF offers a comprehensive air filtration portfolio to provide clean air solutions for commercial and industrial applications.
TotalHeat Exchanger HRV (Heat Reclaim Ventilation) 4PW90548-1 (2014.03) Dimensions (See figure 1 (A = Models 350F~1000F, B = Models 1500F~2000F)) Installation Installation position Example of Installation, VAM500F (See figure 2), VAM800F (See figure 3), VAM2000F (See figure 4) - Places subjected to high temperature or direct flame.
Product Highlights Product Range Capacities View AR View 360 DX coil cooling capacity Airflow rate 500-950 m3 /h Daikin’s HRV Heat Reclaim Ventilation recovers heat energy lost through ventilation and holds down room temperature changes caused by ventilation, thereby maintaining a comfortable and clean environment. Equipped with a heat reclaim ventilator and a heat exchanger DX coil, VKM series is capable of minimizing room temperature fluctuations. VKM series maintains comfortable indoor air quality IAQ by adding fresh outdoor air having nearly the same temperature and humidity conditions as the indoor air. Thus, VKM ensures optimum comfort and further reduces air conditioning load. VKM – How It Works The fresh air is supplied to the office by air discharge grills connected to the VKM Supply Air duct. Heat Reclaim Ventilator + Heat Exchanger → Comfortable Air Supply Equipped with a heat reclaim ventilator and a heat exchanger, the new VKM series minimizes room temperature fluctuations. A Compact Unit Packed with Daikin’s Cutting-Edge Technologies. Air Conditioning and Outdoor Air Processing Can be Accomplished Using a Single System. When the VKM series units are connected, the total connection capacity index must be 50% to 130% of the capacity index of the outdoor units. Filtration Unit Option Removes particulate matter present in the outdoor air, as well as sulfur oxides and nitrogen oxides, providing clean fresh air to the indoor ambient. • filter Removes 99% or more of μm particulate matter. • Activated Carbon filter Removes sulfur oxides and nitrogen oxides Double-layered efficient filtration filters are double-layered. filters are double-layered. 1. The front filter effectively remove large particles. 2. The filter layer contains a large amount of static electricity to capture particulate matter effectively. Electrostatic Dust Collection Filter More Efficient and Longer Lasting Effect The filter layer contains a large amount of static electricity to capture particulate matter effectively, including those smaller than the grid mesh. The filter is difficult to be blocked by particles and has good ventilation and long life span. CO2 Sensor Optional Kit Connection for VAM / VKM Series The CO2 sensor controls airflow so that it best matches the changes of CO2 level in the room. This prevents energy losses from over-ventilation while maintaining indoor air quality with optional CO2 sensor. Tech specs Specifications ModelVKM50GCVEVKM80GCVEVKM100GCVE Power Consumption Heat Exchange modeW 270/230/170390/335/220440/370/260 Power Consumption Bypass modeW305/260/200390/335/220440/370/260 External static Pressure Pa210/170/140220/180/125170/120/90 Airflow rate m3/h500/500/440750/750/640950/950/820 Sound level Heat Exchange modedB43/ Sound level Bypass modedB43/41/ Temp exchange efficiency %76/76/ Enthalpy exchange efficiency %64/64/6766/66/6862/62/66 DX-coil Capacity kW Dimensions H x W x D387x1764x832387x1764x1214387x1764x1214 Machine weight kg92113115 You are now leaving Daikin Malaysia Once you link to another web site, you are subject to the terms and conditions of that web site, including but not limited to its privacy policy. CANCEL CONTINUE
Daikins HRV (Heat Reclaim Ventilation) VAM is a complete energy-efficient solution which About Daikin's ventilation range Daikin are renowned for their reliability, quality of build and innovation within the air conditioning industry. From 150 to more than 140,000 m³/h, the Daikin ventilation range offers a solution for
Daikin Advantage Improved Air Quality A steady inflow of fresh, conditioned air improves air quality of indoor settings. Energy Efficiency Energy recovery between supply air and exhaust air eliminates waste to realize efficient ventilation. Flexible Installation Daikin’s unique modular system enables each unit to be tailor-fitted to the exact dimensions required. Product Lineup Refreshes stale indoor air with fresh outdoor air. Processes outdoor air to bring it near temperature of indoor air and distributes the air throughout the room. Indoor humidity is appropriately controlled by humidification and/or dehumidification. Outdoor-Air Processing Unit Supplying outdoor air at the same temperature of the room maintains comfort and lessens heat load caused by ventilation. * Can be connected only to VRV Heat Reclaim Ventilator Daikin’s unique heat exchange element realizes efficient heat exchange between supply air and exhaust air. High external static pressure enables flexible installation. Heat Reclaim Ventilator with DX-Coil A temperature adjustment function has been added to the Heat Reclaim Ventilator to better maintain comfort and lessen heat load caused by ventilation. * Can be connected only to VRV DESICA*:Heat Pump Desiccant Humidity Control Outdoor-Air Unit The DESICA permits individual control of humidity and temperature, by the hybrid DESICA element which contains a water absorption material and a heat exchanger, with lower energy consumption compared to conventional humidity control devices according to Daikin tests. * DESICA is a Daikin registered trademark in Japan. Technology Heat Exchange Element The thin film material allows only small water molecules moisture to penetrate while blocking out larger molecules such as CO2 . This eliminates waste by preventing the heat and moisture of the conditioned air from escaping outdoors and promotes efficient ventilation using less energy. Learn More Daikin's Unique Heat Pump Desiccant The heat pump desiccant integrates the heat exchanger and desiccant element to enable highly-efficient dehumidification and humidification with no need to supply or drain water. Learn More Wired Remote Controller Stylish Remote Controller Sleek stylish design DAIKIN APP for Installer simplifies the advanced settings such as field settings Useful administration / Shorter and Easier installation Stylish Remote Controller Navigation Remote Controller Operation is easy and smooth, just follow the indication on the remote controller Weekly schedule can be set 5 actions per day for each day of the week Circulation airflow, a function for the latest cassette type can be set Simplified Remote Controller Simple operation by using only six buttons, and users have direct access to basic functions Intuitive design by using pictograms enables user-friendly interface Overseas guests at hotels understand functions without having to know a foreign languages Case Study Case Study Visit the Daikin Global Case Studies page for detailed examples of installations Learn More After Sales Service A global support system delivers timely solutions to all needs. Learn More Preventive Maintenance Service AVAILABILITY The products or features on this page may not be available in your region. Please visit your local website for details on the products and features available in your region.

Гаматана Daikin за запазване на топлината при вентилация подобрява енергийната ефективност и осигурява

Air Treatment Equipment CEK HARGA=> KATALOGUE=> SPESIFIKASI=> Heat Reclaim Ventilator — VAM series Model Names VAM150GJVE, VAM250GJVE, VAM350GJVE, VAM500GJVE, VAM650GJVE, VAM800GJVE, VAM1000GJVE, VAM1500GJVE, VAM2000GJVE Improved Enthalpy Efficiency*1 Higher External Static Pressure*2 Enhanced Energy Saving Functions Seri VAM ini memberikan efisiensi entalpi yang lebih tinggi*1, karena kinerja elemen film tipis yang sangat ditingkatkan. Selain itu, tekanan statis eksternal yang ditingkatkan*2 menawarkan lebih banyak fleksibilitas untuk pemasangan. Seiring dengan ketiga peningkatan luar biasa ini, operasi pendinginan malam hari gratis berkontribusi pada konservasi energi dan lingkungan yang lebih nyaman.
TotalHeat Exchanger HRV (Heat Reclaim Ventilation) 4PA - 2017.08 Operation manual 2 Names of parts Refer to figure 1 (models VAM350~1000F) and figure 2 (models VAM1500~2000F) Operation Explanation for systems This product is operated differently depending on the system configuration.
Residential Light Commercial Commercial Home > Commercial > Ventilation Units > Energy Recovery Ventilator VAM_GVJU Overview Features Resources This product is designed to maintain good indoor air quality by providing sufficient levels of fresh outside air and recover waste heat from extracted air leaving the conditioned zone. This new ERV unit is fully compatible with Daikin’s DIII-NET communications. Provides energy-saving heat recovery ventilation via a new heat exchanger with high temperature and enthalpy recovery efficiency Design flexibility thanks to high static pressure fans and the capability for use in a wide range of climates 5°F to 122°F DB and 80% RH or less* Wide range of functions such as independent operation, interlock with other HVAC systems and automatic night purge to reduce cooling loads and increase energy savings Interlocked simultaneous operation with VRV indoor units through a single controller Auto mode switches the ventilation mode total heat exchange mode to bypass mode according to the operating status of air conditioner system Pre-cooling/heating control function to delay the start of ventilation during air conditioner start-up for higher energy savings Supply and exhaust fresh-up operation modes to control pressure within a space Filter sign and display reset notifies when filter changes are required ESP as high as Sound levels as low as dBA for sound sensitive installation locations * Note Certified in accordance with the AHRI ERV Certification Program, which is based on AHRI Standard 1060. Certified units may be found in the AHRI Directory at Performance characteristics certified to AHRI Standard 1060 based on the following conditions - The cooling effectiveness shall be based on 95°F DB / 78°F WB for the entering supply air and 75°F DB / 63°F WB for the entering exhaust air, at a leaving supply airflow of both 100% and 75% of the rated airflow. - The heating effectiveness shall be based on 35°F DB / 33°F WB for the entering supply air and 70°F DB / 58°F WB for the entering exhaust air, at a leaving supply airflow of both 100% and 75% of the rated airflow. UnityAir-con Systems - Offering Daikin Heat Reclaim Ventilation System, Ventilation Systems, Air Ventilation, एयर वेंटिलेशन सिस्टम, वायु-संचालन प्रणाली in Delhi, Delhi. Get best price and read about company. Get contact details and address| ID: 11360450997 Product Highlights View AR View 360 Fresh air supply and better indoor air quality for confined space. Air flow rate 150 – 2,000 m³/hour Daikin’s HRV Heat Reclaim Ventilation recovers heat energy lost through ventilation and holds down room temperature changes caused by ventilation, thereby maintaining a comfortable and clean environment. This also curbs the load on the air conditioning system and conserves energy. In addition, the HRV is interlocked to Daikin’s VRV system, SkyAir and other air conditioning systems and automatically switches over ventilation mode, further increasing the effects of energy conservation. HRV operation has been centralized on the air conditioner remote controller allowing total control over air conditioning and ventilation with a simple configuration. VAM – How It Works The fresh air is supplied to the office by air discharge grills connected to the VAM Supply Air duct. Heat Recovery Ventilation with Simultaneous Supply and Exhaust A compact unit packed with Daikin’s cutting-edge technologies The heat exchange element uses a upgraded High Efficiency Paper HEP that has superior moisture-absorption and humidifying properties and doubles the current efficiency of moisture absorption. The heat exchange unit speedily recovers heat contained as latent heat vapor. The element is made of a material with superior flame-resistant properties and is treated with an anti-molding agent. Advanced Energy-Saving Ventilation by Interlocking with VRV Indoor Unit • Pre-cool, Pre-heat control • Auto-ventilation mode changeover switching • Night-time free cooling operation Air Conditioning Load Reduced by Approximately 31%* Filtration Unit Option Removes particulate matter present in the outdoor air, as well as sulfur oxides and nitrogen oxides, providing clean fresh air to the indoor ambient. • filter Removes 99% or more of μm particulate matter. • Activated Carbon filter Removes sulfur oxides and nitrogen oxides Double-layered efficient filtration filters are double-layered. filters are double-layered. 1. The front filter effectively remove large particles. 2. The filter layer contains a large amount of static electricity to capture particulate matter effectively. Electrostatic Dust Collection Filter More Efficient and Longer Lasting Effect The filter layer contains a large amount of static electricity to capture particulate matter effectively, including those smaller than the grid mesh. The filter is difficult to be blocked by particles and has good ventilation and long life span. CO2 Sensor Optional Kit Connection for VAM / VKM Series The CO2 sensor controls airflow so that it best matches the changes of CO2 level in the room. This prevents energy losses from over-ventilation while maintaining indoor air quality with optional CO2 sensor. You are now leaving Daikin Malaysia Once you link to another web site, you are subject to the terms and conditions of that web site, including but not limited to its privacy policy. CANCEL CONTINUE
CleanAir stock a large range of air ventilation and diffusion hardware, used to and create individual systems bespoke to client requirements. As a starting point the forms of ventilation to consider are: Ventilation and Heat Reclaim units for air conditioned climate control. Evaporative Air Conditioning for fresh air ventilation and cooling.
Product categoryVRV Air Conditioner›Heat Reclaim VentilationModel HRV VAM250GJVE, VAM500GJVE, VAM650GJVE, VAM800GJVE, VAM1000GJVE, VAM1500GJVE, VAM2000GJVESpecificationMODELVAM250GJVEVAM500GJVEVAM650GJVEVAM800GJVEVAM1000GJVEVAM1500GJVEVAM2000GJVEPower Supply1-phase, 220-240 V/ 220 V, 50 HzTemp. ExchangeEf ciency50/60 HzUltra-High%75/7574/7475/7572/7278/7872/7277/77High75/7574/7475/7572/7278/7872/7277/77Low79/7980/ ciency50/60 HzFor HeatingUltra-High%71/7267/ CoolingUltra-High%63/6355/5561/6161/6164/6461/6162/62High63/6355/5561/6161/6164/6461/6162/62Low66/6659/ HzHeatExchangeModeUltra-HighW137/141248/270342/398599/680635/7601,145/1,3001,289/1,542High120/125225/217300/332517/597567/648991/1,1441,151/1,315Low60/59128/136196/207435/483476/512835/927966/1,039Bypass ModeUltra-HighW137/141248/270342/398599/680635/7601,145/1,3001,289/1,542High120/125225/217300/332517/597567/648991/1,1441,151/1,315Low60/59128/136196/207435/483476/512835/927966/1,039Sound Level 50/60 HzHeat ExchangeModeUltra-HighdBA27-29/ ModeUltra-HighdBA steel plateInsulation MaterialSelf-extinguishable polyurethane foamDimensions HXWXDmm278X810X551306X879X800338X973X832387X1,111X832387X1,111X1,214785X1,619X832785X1,619X1,214Machine Weighkg2432455567129157Heat Exchange SystemAir to air cross ow total heat Sensible heat+latent heat exchangeHeat Exchange Element MaterialSpecially processed non-ammable paperAir FilterMultidirectional brous eecesFanTypeSirocco fanAir ow Rate50/60 HzUltra-Highm3/h250/250500/500650/650800/8001,000/1,0001,500/1,5002,000/2,000High250/250500/500650/650800/8001,000/1,0001,500/1,5002,000/2,000Low155/155320/295500/470700/670860/8401,320/1,2601,720/1,580External Static Pressure50/60 HzUltra-HighPa70/96105/15085/125133/170168/192112/150116/ Duct Diametermmø150ø 200ø 250ø 350Unit ambient condition-15°C–50°CDB, 80%RH or lessAS A PART OF CONTINOUS DEVELOPMENT AND UPGRADATION THE PRODUCT IMAGE/ACCESSORY/FEATURE/SPECIFICATION MAY BE DIFFERENT FROM ACTUAL PRODUCT AT THE TIME OF PURCHASE.
CarrierChillers Used with Heat Recovery. Buildings are responsible for 40 percent of total energy consumption. Of the energy consumed in commercial buildings, 43 percent is used for space and water heating. If a more efficient means of providing heat could be implemented it would represent a tremendous opportunity to reduce energy consumption
WhyDaikin. Daikin guarantees your comfort in every facet of our service, right through from research and development to installation and enjoyment. Malfunction of transmission (between heat reclaim ventilation unit and fan unit) Possible Cause: • Defect of fan unit PCB. • Defect of connecting wire between (1) and (2) Malfunction Code: 95 03** Daikin Europe N.V. est autorisé à compiler le Dossier de Construction Technique. 04 ** Daikin Europe N.V. is bevoegd om het Technisch Constructiedossier samen te stellen. 05 ** Daikin Europe N.V. está autorizado a compilar el Archivo de Construcción Técnica. 06 ** Daikin Europe N.V. è autorizzata a redigere il File Tecnico di
\n daikin heat reclaim ventilator
Thisenergy-saving heat reclaim ventilator further reduces air conditioning load. Air quality improvement including BPO offices with VKM Supports both 50/60 Hz power supply Equipped with DCmotor Conventional modelNew model 270 W 560 W Power consumption reduced by about 51% 220 Pa New model 170 Pa Conventional model
Ventilation • Heat Reclaim Ventilation 1 •HRV•VAM-FA8VE TABLE OF CONTENTS VAM-FA8VE Daikin's HRV Other types Dust does not fall off from the air filter because the air supply fan of the interlocked indoor unit remains activated even when the HRV is operated independently. B8TdFB.